Workshop on Enhancing Diagnostic Accuracy: Strategies to Mitigate Lipemic Interference in Urea and Creatinine Testing Using Alpha-Cyclodextrin
DOI:
https://doi.org/10.35451/cn0g6c80Keywords:
Workshop, Lipemic Serum, Alpha-Cyclodextrin, Urea, CreatinineAbstract
The quality of blood samples dictates the validity of clinical laboratory testing. Lipemic serum conditions frequently cause analytical issues due to high lipid particles that interfere with photometer readings in chemistry analyzers. This community service (PkM) program, formatted as a workshop, was implemented to broaden the knowledge and technical proficiency of laboratory personnel. The event involved 30 students from the Medical Laboratory Technology program as participants. The implementation included interactive lectures, visual demonstrations, in-depth discussions on clinical chemistry principles, and hands-on sample management practices in the laboratory. Educational and training materials were specifically designed to ensure that participants could effectively resolve lipid interference and understand the function of alpha-cyclodextrin as a safe clearing agent that does not alter analyte concentrations. The results demonstrated tangible progress among participants in detecting analytical interference caused by lipemia, evidenced by a 33.5-point average increase in cognitive knowledge scores and a 95.0% participant satisfaction rate. Participants are now capable of executing correct pre-analytical steps using alpha-cyclodextrin and obtaining more accurate urea and creatinine measurements. This program underlines the importance of integrating technical problem-solving into human resource competency enhancement activities in the laboratory. Improving participants' understanding of managing problematic specimens contributes directly to enhancing the quality of clinical chemistry examination results and supports the creation of professional, precise, and reliable healthcare services for the community..
References
[1] A. Izzati and A. Riyani, "Variasi Konsentrasi Alfa Siklodekstrin dan Waktu Sentrifugasi Dalam Preparasi Serum Lipemik Pada Pemeriksaan Glukosa Metode GOD-PAP," Jurnal Teknologi Laboratorium, vol. 7, no. 1, p. 31, 2018, doi: 10.29238/teknolabjournal.v7i1.121.
[2] D. P. Elder, "Biopharmaceutical classification system based-biowaiver harmonization," in Time-Proof Perspectives on Bioequivalence, pp. 275–296, 2023.
[3] D. R. Block, M. A. Lasho, L. J. Donato, and J. W. Meeusen, "Establishing lipemia interference limits," Am. J. Clin. Pathol., vol. 162, no. 4, pp. 356–368, 2024.
[4] E. Khotimah and N. N. Sun, "Analisis Kesalahan Pada Proses Pra Analitik Dan Analitik Terhadap Sampel Serum Pasien Di Rsud Budhi Asih," Jurnal Medika Hutama, vol. 3, no. 4, pp. 402–406, 2022.
[5] I. Permatasari, "Gambaran Kadar Trigliserida pada Serum Lipemik," Journal of Geotechnical and Geoenvironmental Engineering ASCE, vol. 120, no. 11, p. 259, 2015. (Catatan: Teks gabungan "Marbun RA. Uji Aktivitas Ekstrak Daun Pirdot..." telah dihapus karena merupakan kesalahan penggabungan dua referensi yang berbeda).
[6] J. Tandi, A. Wulandari, et al., "Efek Ekstrak Etanol Daun Gendola Merah (Basella alba L.) terhadap Kadar Kreatinin," Galenika Journal of Pharmacy, vol. 3, no. 2, pp. 93–102, 2017, doi: 10.22487/j24428744.2017.v3.i2.8813.
[7] K. M. Ho, C. Chen, J. W. S. Setoh, W. T. T. Yap, and R. C. W. Hawkins, "Optimization of hemolysis, icterus and lipemia interference thresholds," Pract. Lab. Med., vol. 25, p. e00232, 2021.
[8] K. T. Pamungkas, H. Anggraini, and B. Santosa, "Gambaran Kadar Ureum Pada Penderita Hipertensi di Klinik BPJS daerah Mangkang," Angewandte Chemie International Edition, vol. 6, no. 11, pp. 951–952, 2018.
[9] Kamil and A.A.E.N.Putri, “Pemeriksaan Ureum dan Kreatinin Menggunakan Automated Chemistry Analyzer Biolis 24i Premium di RSUD Abdul Wahab SJahranie Samarinda,” Jurnal Teknologi Laboratorium Medik 2022. [Online]. Available :https://jurnal.itkeswhs.ac.id/index.php/mlt/article/view/1070
[10] N. Nikolac Gabaj, M. Miler, and I. Vukasovic, "Lipemia interference in clinical chemistry: mechanisms and management," Biochem. Med., vol. 32, no. 1, p. 010501, 2022.
[11] R. Handriani, Y. Nurfitriani, and D. Mahmud, "Pengaruh Penambahan Alfa Siklodekstrin Terhadap Plasma Lipemik Pada Pemeriksaan Prothrombin Time (Pt) Dengan Metoda Manual," Jurnal Teknologi Laboratorium Medik, vol. 6, no. 1, pp. 17–22, 2022.
[12] S. ArulVijayaVani, P. S. Mohanraj, and R. Reeta, "Evaluating interference of lipemia on routine clinical biochemical tests," J. Lab. Physicians, vol. 15, no. 2, pp. 269–275, 2023.
[13] S. Hartini and D. Suryani, Manajemen Laboratorium Klinik. Yogyakarta: Nuha Medika, 2016.
[14] S. X. Soh et al., "Lipid removal techniques in clinical chemistry testing," Clin. Chem. Lab. Med., vol. 60, no. 2, pp. 152–161, 2021.
[15] W. M. Sari, N. R. Hardisari, and Sujono, "Perbedaan Kadar Kreatinin Pada Serum Lipemik Yang Diolah Dengan Polyethylene Glycol High Speed 6000 8% Dan Sentrifugasi," Jurnal Teknologi Kesehatan, vol. 13, no. 1, pp. 45–49, 2017.